Abstract

The article analyzes the uneven loading of the scraper conveyor electric motors. The most common type of multi-motor conveyor is considered here: two-drive, with head and end drives connected through gearboxes and sprockets by an endless chain with scrapers. The simulation results are presented for three variants of com-binations of parameters of electric drives. It has been established that the use of a two-motor variable frequen-cy drive of a scraper conveyor powered by a single frequency converter inevitably entails uneven loading of the electric motors of the head and end drives. To eliminate this disadvantage, it is proposed to supply each electric motor from its own frequency converter. A system of automatic load balancing is proposed. The implementation and the result of the work of the load balancing system are carried out on a model in the Matlab / Simulink system.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call