Abstract

Clock pulse interpolation method which relies on the software implementation is widely used in the measurement occasions when grating is used. For the displacement less than a grating pitch, common method is to estimate it using adjacent cycle information based on constant speed model or linear model. When the measured object moved with constant speed, these two methods would not introduce errors. However, when the measured object moved with constant acceleration or constant jerk, principle errors would be produced in these two methods. For this problem, this paper developed a method to measure the displacement less than one cycle in clock pulse interpolation method’s applications based on constant acceleration model. Simulation result demonstrated that this method will not introduce error when the measured object moves with constant acceleration, and its overall effect is better than the estimation effect using constant speed model or linear model when the object moves with constant jerk.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.