Abstract

For the question of circulation wind emerged in the process of using long compression and short pumping ventilation dust removal system, a new model of air volume matching was proposed, and the empirical formula of the key process parameters such as axial and radial air volume, axial and radial air out distance were derived according to the relevant theories of air jet in the confined space. Then the 20106 return roadway of fully mechanized working face in Wang Jia Ling coal mine was selected to conduct field verification tests. The result showed that the new air volume catching model had good adaptability, and the key process parameters obtained by theoretical calculation and field test were basically identical. Under the condition of optimum technological parameters, the total dust and respiratory dust concentration of the driver’s place can be reduced 91.98% and 89.53% respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.