Abstract

The representativeness of measurements monitored in earth dams is analysed to investigate how a given measured quantity can be used to interpret the dam's mechanical behaviour. Representativeness is evaluated on the basis of spatial continuity of the measured quantity and the sensitivity of that quantity to natural mechanical nonhomogeneity. The discussion is supported by results from case studies and numerical examples. The study is mainly focused on pore-water pressure measurements. Spatial continuity of pore-water pressure is analysed with consideration of both saturation and drainage conditions. The paper discusses how pore-water pressure representativeness can vary over the lifetime of the dam.Key words: earth dam, pore-water pressure, monitoring.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.