Abstract

Summary Repeatability of measurements of peak and mean tracheal and pharyngeal pressures in exercising horses was determined. Five athletically fit horses were subjected to repeated (n = 5) standardized exercise trials. Static pressures in the trachea, nasopharynx, and mask were determined. At least 96% of all mean pressure measurements were within 5 cm of H2O of the mean value for any horse. Peak pressure measurements were less repeatable, but at least 96% of all measurements were within 10 cm of H2O of the mean peak measurements for any horse. In 10 horses galloping at 14 m/s, the 95% confidence interval for peak treacheal and pharyngeal inspiratory pressures ranged from —40 to —50 cm of H2O and —20 to — 26 cm of H2O, respectively. During expiration, the 95% confidence interval for peak tracheal and pharyngeal pressure at the same speed ranged from 15 to 28 cm of H2O and 10 to 24 cm of H2O respectively. During inspiration, horses with induced laryngeal hemiplegia had static pressure measurements generally outside that range. We conclude that determination of tracheal and pharyngeal pressures is a potentially useful adjunct for assessment of the proximal portion of the respiratory tract.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.