Abstract

Non-thermal plasma (NTP) and combined plasma-MnO2 catalytic (CPMC) air cleaners were tested for removal of low-concentration benzene in air. Both air cleaners were made of stainless steel needle matrix plate and used DC corona discharger. The effects of discharge power and relative humidity (RH) on benzene removal efficiency were investigated in a closed chamber. The intermediate products produced in purification processes were analyzed using gas chromatography-mass spectrometer (GC-MS). The concentrations of discharge byproducts and CO2 selectivity produced in both processes were also compared. It was found that the benzene removal efficiency increased with discharge power in both systems; With the increase of RH in air, benzene removal efficiency firstly increased and then decreased in NTP while it gradually decreased in CPMC. For a fixed discharge power of 9 W and RH of 20% in CPMC, the conversion of benzene increased from 82.9% to 89.6%, the CO2 selectivity increased from 38% to 80%, the concentration of O3 decreased from 25.3 ppm to 1.3 ppm, and NO2 formation decreased from 234 ppm to 25.7 ppm, compared with NTP.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call