Abstract

This paper describes the removal of fluoride from water using granular red mud (GRM) according to batch and column adsorption techniques. For the batch technique, the experiments demonstrated that maximum fluoride removal was obtained at a pH of 4.7 and it took 6 h to attain equilibrium and equilibrium time did not depend upon the initial fluoride concentration. Kinetics data were fitted with pseudo-second-order model. The Redlich–Peterson and Freundlich isotherm models better represented the adsorption data in comparison to the Langmuir model. Column experiments were carried out under a constant influent concentration and bed depth, and different flow rates. The capacities of the breakthrough and exhaustion points decreased with increase of the flow rate. Thomas model was applied to the experimental results. The modelled breakthrough curves were obtained, and they were in agreement with the corresponding experimental data. The column adsorption was reversal and the regeneration operation was accomplished by pumping 0.2 M of NaOH through the loaded GRM-column.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.