Abstract

This study evaluated by the efficacy of rotary and reciprocating systems to remove filling material by micro-CT. Sixty human canines were instrumented up to F3 by ProTaper Universal system and filled with AH Plus/ gutta-percha. Specimens were submitted to 1,200 thermal cycles, scanned by microCT SkyScan 1176 and randomly distributed in groups according to the filling material removal protocol (n = 10): ProTaper Universal, ProTaper Universal/xylol, ProTaper Next, ProTaper Next/xylol, Reciproc and Reciproc/xylol. After filling removal, specimens were analyzed by microCT to separately verify the presence of gutta-percha and sealer remnants. The data (mm3) were analyzed by two way ANOVA and Tukey´s test (5%). For the remaining gutta-percha, the use of xylol provided the highest values for Reciproc (7.60 ± 0.73), which was statistically different from the other groups (p < 0.05) that presented lower values and were statistically similar to each other (p > 0.05). For the remaining sealer, xylol provided the highest values (21.25 ± 6.94) different (p < 0.05) from the use of instruments alone (11.47 ± 9.45). ProTaper Next presented the lowest values (8.16 ± 1.37) for the remaining sealer, different (p < 0.05) from that of Reciproc (24.67 ± 6.32). The qualitative analysis revealed that all groups presented some remaining root filling material, with the highest volumes presented by Reciproc and Reciproc/xylol. In conclusion the rotary systems provided greater removal of filling material regardless of the use of xylol. The use of xylol negatively interfered with the action of the reciprocating system in the removal of the gutta-percha and sealer.

Highlights

  • This study evaluated by the efficacy of rotary and reciprocating systems to remove filling material by micro-CT

  • Considering that during endodontic retreatment, the action of instruments on the root canal wall is a primary factor for the removal of filling material and that xylol may favor the softening of gutta-percha, this study aimed to evaluate the effectiveness of rotary and reciprocating systems associated with or without xylol in the removal of the filling material, using micro-computed tomography

  • Preliminary micro-CT scanning The total sample size for this study was calculated on the basis of a previous research study that used micro-computed tomography scans to evaluate the removal of filling material by using rotary systems.[11]

Read more

Summary

Introduction

This study evaluated by the efficacy of rotary and reciprocating systems to remove filling material by micro-CT. Specimens were analyzed by microCT to separately verify the presence of gutta-percha and sealer remnants. For the remaining gutta-percha, the use of xylol provided the highest values for Reciproc (7.60 ± 0.73), which was statistically different from the other groups (p < 0.05) that presented lower values and were statistically similar to each other (p > 0.05). Xylol provided the highest values (21.25 ± 6.94) different (p < 0.05) from the use of instruments alone (11.47 ± 9.45). The qualitative analysis revealed that all groups presented some remaining root filling material, with the highest volumes presented by Reciproc and Reciproc/xylol. In conclusion the rotary systems provided greater removal of filling material regardless of the use of xylol. The use of xylol negatively interfered with the action of the reciprocating system in the removal of the gutta-percha and sealer

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.