Abstract

Cells of Thiobacillus thioparus TK-m were immobilized on cylindrical porous polypropylene pellets (5 mmφ × 5 mm) which were packed in an acrylic cylinder of 50 mm inner diameter up to the height of 800 mm. When a sulfur-containing malodorous gas was charged to this packed tower at the superficial velocity of 0.1 m/s, maximum loading capacity (mmol/ l·d) for a malodorous gas to attain the removal rate of 95% or more was: 3.65 for dimethyl sulfide, 8.74 for methyl mercaptan, and 17.36 for hydrogen sulfide. At this time, the inlet concentration (μl/ l) of the malodorous compound was: 7.44 for dimethyl sulfide, 17.8 for methyl mercaptan, and 35.4 for hydrogen sulfide. For every compound, higher loading resulted in greater removal quantities. The removal rate of dimethyl sulfide was not overly affected by the presence of a large amount of easily decomposable hydrogen sulfide.