A new single-carrier sensor-less pulsewidth modulation (PWM) method using suggested pseudo reference functions is proposed for packed U-cell (PUC) converter to improve performance and reliability of the PUC converter. It is composed of one PWM carrier signal and two suggested pseudo reference functions. By employing the proposed modulation method, the PUC dc capacitor voltage ripple is substantially decreased, and faster sensor-less capacitor voltage balancing is obtained. Moreover, the power losses are evenly distributed among all power switches. Consequently, notable reduction of the PUC dc capacitor voltage ripple and even distribution of the power loss among switches enhance the PUC converter's reliability and lifetime. In addition, odd multiples of the switching harmonic clusters are eliminated from the output voltage; thus, the values of output passive filter components are halved. Hence, applying the proposed single-carrier sensor-less PWM method remarkably improves the performance, power density, reliability, and lifetime of the PUC converter and notably simplifies implementation of the switching pattern. Provided experimental results and comparisons as well as reliability analysis verify the viability and effectiveness of the proposed PWM method.