Abstract
Cold-formed steel (CFS) columns play a crucial role in modern construction due to their lightweight, prefabricated, and recyclable characteristics, contributing significantly to structural safety and reliability. However, unprotected CFS columns lose their load-bearing capacity within 10-15 minutes under fire conditions. This study reviews recent advancements aimed at improving the fire resistance of CFS columns, focusing on factors such as steel thickness, grade, cross-sectional shape, and fire protection materials. Using ABAQUS software, validated against experimental data, parametric studies reveal that thicker sections and higher-grade steels enhance fire resistance, delaying structural failure. Fire protection strategies, such as plasterboard encasement, further bolster safety. The Complex cross-sectional shape demonstrated the highest load capacity (178.51 kN), while G450 steel outperformed other grades in both load capacity and fire resistance. Columns with 1.95 mm thickness provided the longest failure time (73.49 minutes).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Eksploatacja i Niezawodność – Maintenance and Reliability
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.