Abstract

This experimental study evaluated the interobserver reliability and accuracy of pre-operative digital templating for humeral head size, stem size and neck angle for total shoulder arthroplasty. Twenty-five patients underwent a total shoulder arthroplasty with a single prosthesis. Four independent, blinded surgeons (two experienced shoulder surgeons and two PGY-6 fellows) used pre-operative radiographs and templating software to generate templates of the humeral head, stem and neck for each patient. Interobserver reliability was calculated using weighted kappa (κ) analysis. Accuracy was assessed by comparing templates to actual implant sizes. Interobserver reliability was fair to substantial (κ = 0.26 to 0.71) for head size, fair to substantial (κ = 0.39 to 0.72) for stem size and slight to fair (κ = 0.16 to 0.34) for neck angle. Templated head size, stem size and neck angle had accuracies of 53%, 77% and 68% within one size variation, respectively. Experience did not affect accuracy (p = 0.11 to 0.48). Digital templating is not a useful guide for pre-operative surgical planning and should not be used to select a prosthesis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.