Abstract

BackgroundThe purpose of the present study was to evaluate the mechanical properties of coronary plaques and plaque behavior, and to elucidate the relationship among tissue characteristics of coronary plaques, mechanical properties and coronary risk factors using integrated backscatter intravascular ultrasound (IB-IVUS).MethodsNon-targeted plaques with moderate stenosis (plaque burden at the minimal lumen site: 50-70%) located proximal to the site of the percutaneous coronary intervention target lesions were evaluated by IB-IVUS. Thirty-six plaques (less calcified group: an arc of calcification ≤10°) in 36 patients and 22 plaques (moderately calcified group: 10° < an arc of calcification ≤60°) in 22 patients were evaluated. External elastic membrane volume (EEMV) compliance, lumen volume (LV) compliance, plaque volume (PV) response (difference between PV in systole and diastole), EEM area stiffness index were measured at the minimal lumen site. Relative lipid volume (lipid volume/internal elastic membrane volume) was calculated by IB-IVUS.ResultsIn the less calcified group, there was a significant correlation between EEMV compliance and the relative lipid volume (r = 0.456, p = 0.005). There was a significant inverse correlation between EEM area stiffness index and the relative lipid volume (p = 0.032, r = −0.358). The LV compliance and EEM area stiffness index were significantly different in the diabetes mellitus (DM) group than in the non-DM group (1.32 ± 1.49 vs. 2.47 ± 1.79%/10 mmHg, p =0.014 and 28.3 ± 26.0 vs. 15.7 ± 17.2, p =0.020). The EEMV compliance and EEM area stiffness index were significantly different in the hypertension (HTN) group than in the non-HTN group (0.77 ± 0.68 vs. 1.57 ± 0.95%/10 mmHg, p =0.012 and 26.5 ± 24.3 vs. 13.0 ± 16.7, p =0.020). These relationships were not seen in the moderately calcified group.ConclusionThe present study provided new findings that there was a significant correlation between mechanical properties and tissue characteristics of coronary arteries. In addition, our results suggested that the EEMV compliance and the LV compliance were independent and the compliance was significantly impaired in the patients with DM and/or HTN. Assessment of coronary mechanical properties during PCI may provide us with useful information regarding the risk stratification of patients with coronary heart disease.

Highlights

  • Atherosclerotic changes consist of both a structural and functional component

  • We previously reported that integrated backscatter (IB)Intravascular ultrasound (IVUS) had high sensitivity and specificity (90-95%) for the tissue characterization of coronary plaques using histology as a gold standard [3,4,5,6]

  • The purpose of the present study was to evaluate the mechanical properties of coronary arteries and plaque behavior, and to elucidate the relationship among mechanical properties, tissue characteristics of coronary plaques and coronary risk factors using integrated backscatter intravascular ultrasound (IB-IVUS)

Read more

Summary

Introduction

Atherosclerotic changes consist of both a structural (atherosis) and functional (sclerosis) component. Intravascular ultrasound (IVUS) allows cross-sectional imaging of coronary arteries and provides a comprehensive assessment of atherosclerotic plaques in vivo [2,3]. We previously reported that integrated backscatter (IB)IVUS had high sensitivity and specificity (90-95%) for the tissue characterization of coronary plaques using histology as a gold standard [3,4,5,6]. In those studies, we constructed two-dimensional (2D) or three-dimensional (3D) color-coded maps of plaque components based on the IB values [4,5,6,7,8,9]. The purpose of the present study was to evaluate the mechanical properties of coronary plaques and plaque behavior, and to elucidate the relationship among tissue characteristics of coronary plaques, mechanical properties and coronary risk factors using integrated backscatter intravascular ultrasound (IB-IVUS)

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.