Abstract

A method allowing the evaluation of fire retardancy properties is presented in the case of an intumescent formulation. In that case, the protection is obtained via a condensed mechanism. The method consists in the determination of invariant physicochemical parameters deduced from TG analysis : invariant activation energy and invariant preexponential factor. In the case of fire retardant polypropylene based formulation, there is a correlation between the value given by an evaluation test, i.e. the LOI (ASTM D 2863/77) and the invariant activation energy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.