Abstract

The results of geomonitoring of the technical state of a five-storeyed building erected on driven prismatic piles are presented. The cause of excessive deformations of the foundation base is the inability of the pile tip to reach the design depth, which led to a significant reduction in their load-bearing capacity. The constructive technological solution of strengthening of the bases from piles as a part of a tape grid by bringing under existing grids of a monolithic reinforced concrete slab is improved. A new analytical model of the system “deformed building – driven prismatic piles as a part of a tape grid – soil base with a weak underlying layer” before and after supplying the slab under the existing foundation grids. The stress-strain state (SSS) of this system is estimated using the finite element method (FEM). New data of the change in the SSS system after supplying the slab under the existing grids were obtained. The results of the project execution (without resettlement of the residents of the house) and the respective geomonitoring are presented.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call