Abstract

This paper presents a lab-scale experiment on the prototype of the ½ cycle refrigeration system of an LPG-fueled vehicle. LPG before being sent to the engine is used as a heat absorbing medium. The experiment was carried out at 0.15 MPa evaporation pressure and 1-6 g/s of LPG flow rate which representing of Light Duty Vehicle (LDV) fuel consumption. The results of this study indicate that ½ cycle refrigeration system capable of producing refrigeration effect of more than 1.2 kW with EER of 2.72.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.