Abstract

Abstract It is well known that the ratio of disk friction loss of low specific speed pumps is large. When the specific speed is 100 min−1, m3/min, m or less, the disk friction loss increases remarkably. In this study, focusing on the clearance flow from the diffuser outlet to the impeller outlet (This is called the outward flow) behind the centrifugal pump, a fin was installed on outer diameter side of the rotating wall on the back side of a centrifugal pump as a countermeasure, and the influence of changes in velocity distribution near the wall on disk friction loss was investigated by torque measurements, velocity measurement, and computational fluid dynamics (CFD) analysis. As a result, it was clarified that disk friction loss is decreasing by installing the fin in both torque measurements and CFD results, because the clearance flow is separated by fin and circumferential velocity is increased in the wake region of the fin in both measurements and CFD. In addition, it was clarified that disk friction coefficient (normalized torque) can be expressed as a function of the inlet swirl ratio and Reynolds number. Also, prediction equation is derived for each shape (with and without fin). According to the equation, it was found that disk friction loss reduction effect by installing a fin becomes larger when Reynolds number and the inlet swirl ratio are small.