Abstract
Introduction. In spite of many advantages of radial flux permanent magnet brushless DC motors it suffers from the distinct disadvantage of high cogging torque. The designer must emphasize to reduce the cogging torque during the design stage. This paper introduces magnet shifting technique to mitigate cogging torque of surface mounted radial flux brushless DC motor. Methodology. Initially 200 W, 1000 rpm surface mounted radial flux permanent magnet brushless DC motor is designed with symmetrical placement of permanent magnets with respect to each other on rotor core. Cogging torque profile of this initial motor is obtained by performing finite element modelling and analysis. Originality. This design has been improved by shifting the position of permanent magnets with respect to adjacent permanent magnets. The effect of magnet shifting on cogging torque has been analyzed by performing finite element analysis. Results. It has been examined that the peak to peak cogging torque is decreased from 1.1 N×m to 0.6 N×m with shifting of permanent magnets respectively.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.