Abstract

A reduced common mode voltage (CMV) based DC-link voltage balancing strategy is proposed for a neutral point clamped (NPC) three-level inverter with permanent magnet synchronous machine. Compared to the earlier proposed strategy, it completely eliminates the V dc /2 corresponding CMV by eliminating the two zero voltage vectors (PPP, NNN) from the space vector switching sequences. Hence, it uses only one zero voltage (OOO) vector with the other redundant voltage vectors to produce the reference vector in inner subsectors. Detailed simulation and experimental studies are also carried out to show the effectiveness of the proposed system with DC-link voltage balancing ability. Harmonic distortions are also compared with the previously proposed scheme. Dspace® based real time operating system is used for real time implementation with 6.0 kW surface PMSM.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.