Abstract

The recurrent laryngeal nerve (RLN) does not regenerate well after it has been cut, and no current surgical methods achieve functional regeneration. Here, we evaluate the functional regeneration of the RLN after reconstruction using a biodegradable nerve conduit or an autologous nerve graft. The nerve conduit was made of a polyglycolic acid (PGA) tube coated with collagen. A 10-mm gap in the resected nerve was bridged by a PGA tube in 6 adult beagle dogs (group 1) and by an autologous nerve graft in 3 dogs (group 2). Fiberscopic observation revealed functional regeneration of the RLN in 4 of the 6 dogs in group 1. No regeneration of the RLN was observed in any dog in group 2. We also tested for axonal transport, and measured the compound muscle action potential. The RLN can be functionally regenerated with a PGA tube, which may act as a scaffold for the growth of regenerating axons.