Abstract
For recovery of the rare earth elements neodymium and praseodymium from end-life permanent magnets, solvent extraction experiments were carried out on the nitrate-based leachate with trioctylphosphine oxide (TOPO) as an extractant. TOPO selectively extracted Nd and Pr in preference to Fe at higher HNO3 concentration. Nd and Pr extracted into TOPO were selectively stripped using HCl solution, and the small amount of co-loaded Fe was stripped with ammonium oxalate solution after removal of Nd and Pr. McCabe-Thiele diagrams for the extraction and stripping of Nd/Pr were constructed. The results were validated in counter-current simulation experiments using real leachate solution. Finally, a process for recovering Nd and Pr from the nitric acid leachate of permanent magnets was proposed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.