Abstract

Efforts have been given to improve the turbine blades ability to withstand high temperature for a long period of time by implementing effective cooling system. There are many aspects that should be considered when implementing impingement cooling. This paper will only cover two trending aspects in impingement cooling implementation; the jet-to-target plate distance and the application of ribs in promoting better impingement cooling performance. For target plate distance to impingement jet diameter value, H/d > 1, the area-averaged Nusselt number also decreases as the H/d value increases. This may have been due to a reduction of the amount of momentum exerted by the impinging jets onto the target plate. For H/d < 1, the results have been proven otherwise. Heat transfer in impingement/effusion cooling system in crossflow with rib turbulators showed higher heat transfer rate than that of a surface without ribs because the ribs prevent the wall jets from being swept away by the crossflow and increase local turbulence of the flow near the surface. It could be concluded that both H/d ratio and ribs installation play an important role in enhancing impingement cooling systems heat transfer effectiveness.