Abstract

Using eco-friendly, cheap, and available adsorbents is promising for the determination of metal ions. So, this study focuses on the modification of graphite reinforcement carbon paste electrode (GRCPE) with mango seed kernel (MSK) for voltammetric determination of Cd(II). Moreover, to increase the surface area of this adsorbent, it was prepared in nanosized that formed nanoparticles of mango seed kernel (MSK-NPs). The developed nanocomposite electrode of carbon paste electrode modified with nanoparticles of mango seed kernel (MSK-NPs@GRCPE) was characterized using Fourier transform infrared (FTIR) and Scanning electron microscopy (SEM). The effect of pH, buffer solution, and supporting electrolyte as experimental conditions were optimized through differential pulse adsorptive anodic stripping voltammetric method (DPAdASV). Britton-Robinson buffer pH = 3.9 at Eacc = – 1400 mV, tacc = 30 s, pulse width = 10 ms and sampling time = 8 ms were the optimum conditions for determination of Cd(II). The LOD and LOQ of MSK-NPs@GRCPE were calculated at 5.44 × 10–9 and 1.65 × 10–8 M, respectively. Compared with bare graphite reinforcement carbon paste electrode (BGRCPE), the nanocomposite MSK-NPs@GRCPE has a lower detection limit, indicating that the presence of MSK-NPs could greatly improve the response to Cd(II). The practical applicability of the electrode was verified by the determination of Cd(II) in chocolate and white rice samples. The results show high selectivity and sensitivity for Cd(II) in real samples.Graphical abstract