Abstract

The real-time feedback control of electron density was performed in an inductively coupled plasma (ICP). A 36 GHz heterodyne interferometer was adopted as the sensor for electron density measurement. The actuator was rf power which drove the ICP antenna. The results show that the electron density in an ICP system is a type 0 system. Therefore, a proportional-integral controller is necessary to eliminate steady-state error. A prefilter was designed to smooth the desired step change of electron density so that the variation of rf power became mild. A feedforward compensator was added to reduce the disturbance effect resulting from pressure change. The experimental results showed that the control system could quickly track the desired electron density and compensate the electron density variation resulting from pressure disturbance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.