To evaluate the ability of quadruple Taqman probe real-time PCR to the detection of vanA, vanB and vanM in enterococcal isolates. A total of 343 strains, including 253 vancomycin-resistant enterococcus (VRE) strains and 90 non-VRE strains, were tested by both quadruple Taqman probe real-time PCR and gel-based PCR assay. When differentiating among three genotypes of vanA, vanB and vanM in VRE strains, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), diagnostic accuracy and consistency of the quadruple Taqman probe real-time PCR were all 100%. Minimum. Inhibitory concentration (MIC) results showed that there was a wide MIC range of vancomycin and teicoplanin for the strains that harboring vanA/vanM gene respectively or harboring vanA and vanM genes simultaneously. However, the VRE strains with vanB genotype all were sensitive to teicoplanin. Considering the excellent PPV and low NPV, real-time PCR would be useful to monitor VRE-colonized or infected patients. However, further evaluation of the assay's performance in the clinical specimens is required, especially when considering that high level of PCR inhibitors present in these samples.