Abstract

Quartz crystal microbalance (QCM) biosensor integrated in a flow injection analysis (FIA) system was used for the investigation of the specific interaction between immunoglobin G (IgG) and histidine. The histidine was immobilized on the gold electrodes of the piezoelectric crystal using appropriate procedures based on self-assembling of the dithiothreitol (DTT). The specific interaction of the immobilized ligand with IgG in solution was followed as a change in the resonant frequency of the modified crystal and studied in real time without any additional labels. With the mass sensitive biosensor system, the differences in affinity of three different species of IgG: human IgG, goat IgG and mouse IgG were easily distinguished and their respective kinetic rate constants (k ass and k diss) and equilibrium association constants (K A) were determined from the curves of frequency versus time. For the interactions, K A were 2.92×10 4, 3.23×10 4 and 4.08×10 4 M −1 for human IgG, goat IgG and mouse IgG, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.