Abstract
The primary objectives of this research work are design and implementation of Third Generation CRONE controller for Air Pressure System (APS). The mathematical modeling is determined using worst case modeling technique for different operating regions. The design and implementation of CRONE control strategy through worst case modelling and examined in real time. The performances of Third Generation CRONE (TGC) controller is compared with ZN-PI controller and the results are tabulated in terms of time domain and error indices. It is validated that the TGC controller gives better performances than ZN-PI controllers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Recent Technology and Engineering (IJRTE)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.