Abstract

AbstractPhysical modeling of floating offshore wind turbines (FOWTs) is challenging due to the complexities associated with the simultaneous application of two different scaling laws, governing the hydrodynamic and aerodynamic loading on the structure. To avoid these issues, this paper presents a real-time hybrid testing (RTHT) strategy in which a feedback loop, consisting of an on-board fan and control algorithm, is utilized to emulate the aerodynamic forces acting on the FOWT system. Here, we apply this strategy to a 70th-scale IEA Wind 15 MW reference wind turbine mounted on a version of the VolturnUS-S platform. Unlike other similar methods, which directly simulate the aerodynamic loads for the fan’s control using an aerodynamic code running in parallel with the experiment, this example utilizes a surrogate model trained on numerical model data calculated in advance. This strategy enables high-fidelity numerical model data, or even physical data, to be included in the aerodynamic emulation, by removing the requirement for real-time simulation, and, therefore, potentially enables more accurate loading predictions to be used in the experiments. This paper documents the development of the real-time hybrid testing system in the Coastal Ocean And Sediment Transport (COAST) Laboratory at the University of Plymouth in the UK, including the hardware, software, and instrumentation setup, and demonstrates the power of the surrogate-based aerodynamic emulator based on numerical data calculated using OpenFAST.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call