Abstract
An interferometric fiber-optic gyroscope (IFOG) demodulates a rotation signal via interferometric light intensity. However, the working environments of IFOGs typically involve great uncertainty. Fluctuations in temperature, air pressure, electromagnetic field, and the power system all cause the power of the superluminescent diode (SLD) light source to fluctuate as well. In this invited paper, we studied the effects of SLD power fluctuation on the dynamic and static performance characteristics of a gyro system through the use of a light-power feedback loop. Fluctuations of 0.5 mA, 1 mA, and 5 mA in the SLD source entering the IFOG caused zero-bias stability to be 69, 135, and 679 times worse. We established an effective method to monitor power fluctuations of SLD light sources and to compensate for their effects without increasing hardware complexity or system cost. In brief, we established a real-time power-sensing and -compensating system. Experimental results showed that for every 0.1 mA increase in the fluctuation amplitude of the driving current, the zero-bias stability became 4 to 7 times worse, which could be reduced about 95% through the use of SLD power compensation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.