Abstract

A rapid method was developed for the extraction and identification of RoHS-relevant organic flame retardants in polymer material. Extraction was carried out using ultrasonic supported solvent extraction (USSE) and isopropanol. HPLC separation was achieved using a reversed-phase phenylhexyl-modified column and methanol, containing 2-aminoethanol-buffered, alkaline water. Identification was carried out by scanning UV detection and comparison with a library assembled from spectra of reference substances. The method was used to extract and identify polymer additives in TV and PC monitor housings. The overall runtime required for extraction and chromatographic analysis is less than 10 min. The limits of detection comply with the recommendations set by the German draft law.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.