A method for the determination of ethynyloestradiol in samples of rabbit plasma containing pentobarbital and heparin, the former used as an anaesthetic and the latter as an anticoagulant, has been developed. Quantification was carried out using a reversed-phase high-performance liquid chromatographic (HPLC) method in isocratic mode at room temperature, with electrochemical detection at an applied potential of +1 V vs. Ag/AgCl. Under these conditions, the retention time for ethynyloestradiol was ca. 2.9 min, the average recovery from plasma was 74.5%, and the limit of detection was 10 pg, corresponding to a plasma concentration of 50 pg/ml using 1 ml of plasma. Natural oestrogens, oestriol, oestradiol and oestrone showed peaks that did not interfere with ethynyloestradiol, and retention times of ca. 0.8, 2.4 and 3.4 min, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.