Abstract

A rapid column elution method has been developed for the determination of ethyl carbamate (EC) in alcoholic beverages. The beverage is mixed with Celite and packed in a column containing deactivated alumina capped with a layer of sodium sulfate. EC is then eluted with methylene chloride. The method, using a gas chromatograph-thermal energy analyzer with a nitrogen converter for detection and quantitation of EC, has been applied to a variety of alcoholic beverages. Recoveries +/- standard deviations of EC in wine and whisky fortified at the 20 and 133 micrograms/kg (ppb) levels averaged 87.3 +/- 5.3 and 88.7 +/- 3.6%, respectively. The method has a limit of detection of 1.5 ppb. Gas chromatography/mass spectrometry/mass spectrometry was used to confirm the identity and quantitation of EC in selected beverage extracts.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.