Abstract

Streak tube imaging lidar (STIL) is an active imaging system that has a high range accuracy and a wide range gate with the use of a pulsed laser transmitter and streak tube receiver to produce 3D range images. This work investigates the range accuracy performance of STIL systems based on a peak detection algorithm, taking into account the effects of blurring of the image. A theoretical model of the time-resolved signal distribution, including the static blurring width in addition to the laser pulse width, is presented, resulting in a modified range accuracy analysis. The model indicates that the static blurring width has a significant effect on the range accuracy, which is validated by both the simulation and experimental results. By using the optimal static blurring width, the range accuracies are enhanced in both indoor and outdoor experiments, with a stand-off distance of 10m and 1700m, respectively, and corresponding, best range errors of 0.06m and 0.25m were achieved in a daylight environment.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call