Abstract
Sixty infants (median gestational age 29 weeks) with acute and 60 infants (median gestational age 25 weeks) with chronic respiratory distress were randomised to be extubated either directly into a headbox or onto 3 cm H2O nasal continuous positive airway pressure (CPAP). Our aim was to test the hypothesis that extubation onto nasal CPAP rather than directly into a headbox was more likely to be associated with successful extubation in infants with acute rather than chronic respiratory distress. Overall the failure rate of extubation was approximately 33%, with no significant difference between the infants with acute and chronic respiratory distress. There was no significant difference in the failure rate of extubation among infants randomised to receive nasal CPAP or headbox oxygen in either the acute or chronic respiratory distress groups.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.