Abstract
Abstract : In most of the literature, accuracies for radiosonde-measured atmospheric moisture are expressed in terms of relative humidity, i.e., the percent of saturation. The report presents the radiosonde-measured atmospheric moisture accuracies in terms of dew point, i.e., saturation temperature. The dew-point root-mean-square (RMS) errors are presented in tables which resulted from the computations and in nomograms for ready use. A table and a nomogram are included for temperatures between 0C and 40C, and another of each for temperatures between -40C and 0C. Dew-point accuracies are least for high temperatures and low dew points and greatest for low temperatures and high dew points in each temperature group, viz., 0C to 40C and -40C to 0C.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.