The TJ-II stellarator presently in operation at the National Laboratory of Fusion is subject to radiological surveillance in compliance with the Spanish Nuclear Regulation. During its pulsed operation hard X-rays are emitted by the runaway electrons, and soft X-rays are generated by bremsstrahlung of thermalized electrons. Inside the experimental hall, the plasma heating systems and some active diagnostics are additional sources of radiation. Outside the experimental hall, some auxiliary systems, such as high-voltage power supplies, must be checked for radiological influence. In order to verify the adequate radiological classification of the different working areas, 15 dosemeters are distributed in radiologically controlled areas close to the machine, as well as in areas of public use in the TJ-II building. The integrated dose equivalent is analyzed to help establish the range of radiological influence of the stellarator. The results of the period 2015-20 are presented and analyzed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.