Abstract

ACJ stabilization using a braided polyester mesh has become popular in ACJ injuries. However, concerns have been raised about excessive anterior clavicle displacement. The purpose of this study was to report radiographic position of the distal clavicle in relation to the acromion after ACJ reconstruction using this device immediately postoperative and after 6 months follow-up compared with a healthy control group.Thirty-eight patients with ACJ instability treated with a braided polyester mesh were compared within group (pre-/postoperatively) and between groups (with age/sex matched controls). Biplane radiographic measurements by 2 observers were made preoperatively, immediate postoperatively and at 6 months follow-up. Inter-observer reliability was assessed and clinical outcome scores were recorded.ACJ stabilization significantly reduced vertical displacement immediately postoperatively (13.8 ± 4.2 to 3.5 ± 5.5 mm; p < 0.0001) towards controls (1.7 ± 2.3 mm,p < 0.0873). Slight further superior displacement (4.4 mm) occurred at 6 months follow-up compared to immediately postoperative (p = 0.0029) and 6.2 mm more than mean controls (p < 0.0001). In the axial plane, significant early reduction of posterior displacement was achieved (10.3 ± 8.0 to 1.1 ± 5.1 mm,p = 0.0240) and the clavicle settled back to a more posterior position at 4.5 ± 6.7 mm at 6 months post-surgery (p = 0.3062). At both time points, posterior displacement was comparable with the controls (3.4 ± 3.0 mm,p = 0.4371 postoperative, p = 0.563 at 6 months follow-up). Excessive anterior displacement has been observed in 2 of the 5 available axial radiographs early postoperative and in 4 of 14 available axial radiographs at 6 months. Constant, Oxford Shoulder and Nottingham Clavicle scores significantly improved (25 ± 12 to 43 ± 7:p < 0.0001, 46 ± 27 to 80 ± 19:p = 0.0038, 53 ± 14 to 80 ± 17:p < 0.0001). ACJ stabilization using a braided polyester device in ACJ instability is effective at reducing both superior and posterior clavicle displacement with excellent clinical outcome. Overcorrection in the axial plane seems to occur, however this is of no clinical and radiographic significance. Posterior displacement is significantly reduced towards control values at 6 months follow-up.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.