Abstract
A method bas been developed for measuring radiation temperatures using a set of absorption-foils coupled to a soft X-ray streak camera in laser plasme experiments. A result has been given for a planar gold target irrdiatcd by laser (λ = 1.053μm) pulses of about 360ps in duration with average intensities of about 1014W/cm2 from the LF-11# Nd: glass laser facility. In addition, applications to measuring time-resolved spectra and space-resolved temperature are discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.