Abstract

Experiments on investigation of the radiation defects produced as a result of high energy proton irradiation of single crystal Si wafers are carried out. Parameters of the proton irradiation facility are presented. It is shown that the most efficient radiation defect formation correlates with the position of the Bragg peak of ionization losses. LT spectra were measured just after irradiation and then after keeping Si samples during 3 months of at room T. We did not observe any variation of the number density of the defects, except for the 7th wafer, where most part of protons was stopped. An efficient annealing of the vacancy-type defects starts at temperatures slightly lower than 100 °C (during 10 min). Annealing at about 700 °C leads to recovering of the monoexponrntial shape of the LT spectra.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.