Abstract
The purpose of this study is to measure the environmental radiation exposure in and surrounding the room of patients treated with (131)I. Absorbed dose rates were measured using thermoluminescence dosemeters, type TLD-200 (CaF(2):Dy), in a continuous monitoring programme. It is found that the estimated annual shallow and deep dose rates are 226 and 175 mGy at the patient bed; 94 and 72 mGy in the bathroom; and 12 and 10 mGy at the visitor chair, respectively. The annual absorbed dose in the corridor is almost at the background level. It is found that the annual doses at the patient bed and in bathroom were above the limit for radiation workers, whereas the dose rate at the visitor chair was within the accepted limit for radiation workers and above the limit for the public.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.