Abstract

Characterization of the Texas Instruments SBP9900A 16-bit microprocessor has been performed in radiation environments. The test results indicate that the devices will remain functional at reduced electrical performance following exposures to ionizing radiation levels of 3×106rads(Si) or neutron fluences of 3×1013n/cm2. Transient logic upset was not observed at ionizing radiation dose rates of less than 1×109rads(Si)/sec. The primary failure mode in the neutron and total ionizing dose environments was found to be a reduction in up-gain of the npn portion of the I2L cell. Methods of enhancing the radiation hardness of the SBP9900A are discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.