Abstract

The goal of the present study was to estimate the radiation dose for a group of 45 Kawasaki disease (KD) patients undergoing fluoroscopically guided cardiac catheterization. The sample of procedures corresponds to a single hospital and was collected in 10years. Anthropometric characteristics and the quantities of air kerma-area product (PKA) among others were recorded for each procedure. Monte Carlo PCXMC 2.0 software was used to estimate organ and effective doses. The PKA value of 7.2Gycm2 was proposed as the local Diagnostic Reference Level for KD. For organ absorbed doses, median values for thyroid, heart, lungs, esophagus, skin, active bone and breast were 1.2; 2.2; 4.6; 2.7; 1.1; 1.2 and 2.7mGy, respectively. For effective dose, the mean value was 2.7±2.5mSv. This paper presents the first patient dose values for the KD using catheterization techniques, in Latin America and the Caribbean Region.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.