An investigation of radiated reliability of HBT and MOSFET which fabricated on 0.35 μm SiGe BiCMOS technology is presented under dose rates of 500 mGy(Si)/s and 1 mGy(Si)/s with a 60Co γ irradiation source. Gummel characteristics of SiGe HBT and transfer characteristics of MOSFET are measured before and after irradiation. Base current (IB), leakage current (IOFF) and threshold voltage (VTH) are extracted from gummel and transfer characteristics. Our results show that there is a slight increase in IB and an observed decrease in β for SiGe HBT device. For NMOS transistor, a conspicuous increase in IOFF and slight drift in vt H . No dose-rate effect has been seen in SiGe HBT devices; however, it has been observed in NMOS transistors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.