Abstract

An experimental study of the normal zone propagation and total resistance as a function of time is described. The normal zone propagation velocity in a single strand was measured as a function of both current and magnetic field with particular interest in the neighborhood of the short sample limit. The study proceeded from measurements in single multifilamentary strands to measurements in 23 strand cables under different cooling environments to finally measurements in actual ramping dipole magnets made with this cable. Interpretation of the results led to the determination of safety limits for the Energy Doubler/Saver magnets and to safeguards implemented by an energy dumping circuit which effectively protects these magnets from self-destruction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.