Abstract
In this paper, we present an electric quench detection method without a central voltage tap which may cause the short-circuit of the lead-wires from the voltage taps in the quench detection of a large AC superconducting coil. In this method, an inductive voltage detection coil is used instead of the central voltage tap. The inductive voltage detection coil is electrically insulated from a superconducting coil and therefore the lead-wires do not break down. Through the quench detection tests for a Bi-2223/Ag HTS coil, we show the feasibility of the proposed method for detecting the quench of the large AC superconducting coil.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.