Abstract

Recently, compressive sampling has received significant attention as an emerging technique for rapid volumetric imaging. We have previously investigated volumetric optical coherence tomography (OCT) image acquisition using compressive sampling techniques and showed that it was possible to recover image volumes from a subset of sampled images. Our previous findings used the multidimensional wavelet transform as the domain of sparsification for recovering OCT image volumes. In this report, we analyzed and compared the potential and efficiency of three other image transforms to reconstruct the same volumetric OCT image. Two quantitative measures, the mean square error and the structural similarity index, were applied to compare the quality of the reconstructed volumetric images. We observed that fast Fourier transformation and wavelet both are capable of reconstructing OCT image volumes for the orthogonal sparse sampling masks used in this report, but with different merits.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.