Abstract

Although intravascular ultrasonography (IVUS) guidance promotes favorable outcomes after percutaneous coronary intervention (PCI), many catheterization laboratories worldwide lack access. To investigate whether systematic implementation of quantitative coronary angiography (QCA) to assist angiography-guided PCI could be an alternative strategy to IVUS guidance during stent implantation. This randomized, open-label, noninferiority clinical trial enrolled adults (aged ≥18 years) with chronic or acute coronary syndrome and angiographically confirmed native coronary artery stenosis requiring PCI. Patients were enrolled in 6 cardiac centers in Korea from February 23, 2017, to August 23, 2021, and follow-up occurred through August 25, 2022. All principal analyses were performed according to the intention-to-treat principle. After successful guidewire crossing of the first target lesion, patients were randomized in a 1:1 ratio to receive either QCA- or IVUS-guided PCI. The primary outcome was target lesion failure at 12 months, defined as a composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization. The trial was designed assuming an event rate of 8%, with the upper limit of the 1-sided 97.5% CI of the absolute difference in 12-month target lesion failure (QCA-guided PCI minus IVUS-guided PCI) to be less than 3.5 percentage points for noninferiority. The trial included 1528 patients who underwent PCI with QCA guidance (763; mean [SD] age, 64.1 [9.9] years; 574 males [75.2%]) or IVUS guidance (765; mean [SD] age, 64.6 [9.5] years; 622 males [81.3%]). The post-PCI mean (SD) minimum lumen diameter was similar between the QCA- and IVUS-guided PCI groups (2.57 [0.55] vs 2.60 [0.58] mm, P = .26). Target lesion failure at 12 months occurred in 29 of 763 patients (3.81%) in the QCA-guided PCI group and 29 of 765 patients (3.80%) in the IVUS-guided PCI group (absolute risk difference, 0.01 percentage points [95% CI, -1.91 to 1.93 percentage points]; hazard ratio, 1.00 [95% CI, 0.60-1.68]; P = .99). There was no difference in the rates of stent edge dissection (1.2% vs 0.7%, P = .25), coronary perforation (0.2% vs 0.4%, P = .41), or stent thrombosis (0.53% vs 0.66%, P = .74) between the QCA- and IVUS-guided PCI groups. The risk of the primary end point was consistent regardless of subgroup, with no significant interaction. Findings of this randomized clinical trial indicate that QCA and IVUS guidance during PCI showed similar rates of target lesion failure at 12 months. However, due to the lower-than-expected rates of target lesion failure in this trial, the findings should be interpreted with caution. ClinicalTrials.gov Identifier: NCT02978456.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.