Abstract

The non-uniformity of the lens array in the segmented planar integrated optical imaging system has not been studied. We design an inhomogeneous multistage sampling lens array based on a hierarchical multistage sampling lens array of the segmented planar integrated optical imaging system by changing the radius of the lenslet for frequency-selective sampling to optimize the design of the UV spatial frequency distribution. The signal transfer model of the proposed imaging system was established considering the radius of the lenslet and key waveguide parameters. Simulation results show that the proposed system produces better imaging quality owing to the selective sampling of frequency. Compared with the homogeneous multistage sampling lens array (radius of 1.8 mm), the optimal radius parameters of the inhomogeneous multistage sampling lens array are given for the same longest lens array length. Detailed calculations of the parameters of the waveguide connected to the lens array were performed. Our results provide a theoretical basis for the optimal design and process of a new segmented planar integrated optical imaging system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.