Abstract

Racecadotril, an anti-secretory medication, has been used as an adjuvant in an oral rehydration therapy for children experiencing severe diarrhea. Racecadotril is quickly converted to thiorphan, an active metabolite, after oral treatment, which mediates all subsequent activities. An efficient and rapid liquid chromatography-tandem mass spectrometry method was developed and fully validated to measure thiorphan in human plasma, using thiorphan-d7 as an internal standard. The extraction method used was protein precipitation while chromatographic separation was achieved using InertSil CN-3 (50 × 2.1 mm, 5 µm column). The assay was linear over the concentration range of 1–200 ng/ml with correlation coefficients of ≥0.9991. The intra- and inter-day precisions were less than 10.0 % for all concentrations investigated. 0.02 % aqueous formic acid and methanol (30:70 v: v) were used as mobile phases, with an analysis time of less than 1 min. This method proved stable under several conditions. The developed method worked well in a three-period pharmacokinetic bioequivalence study after a single oral administration of 100 mg racecadotril to 15 healthy Jordanian volunteers under fasting conditions.