Abstract

Real-time intrafraction tracking/gating is an integral component of magnetic resonance imaging-guided radiation therapy (MRgRT) and may have contributed to the acute toxicity reduction during prostate stereotactic body radiation therapy observed on the MRgRT-arm of the MIRAGE (MAGNETIC RESONANCE IMAGING-GUIDED Stereotactic Body Radiotherapy for Prostate Cancer) randomized trial (NCT04384770). Herein we characterized intrafraction prostate motion and assessed gating effectiveness. Seventy-nine patients were treated on an MR-LINAC. Real-time cine imaging was acquired at 4Hz in a sagittal plane. If >10% of the prostate area moved outside of a 3-mm gating boundary, an automatic beam hold was initiated. An in-house tool was developed to retrospectively extract gating signal for all patients and identify the tracked prostate in each cine frame for a subgroup of 40 patients. The fraction of time the prostate was within the gating window was defined as the gating duty cycle (GDC). A total of 391 treatments from 79 patients were analyzed. Median GDC was 0.974 (IQR, 0.916-0.983). Fifty (63.2%) and 24 (30.4%) patients had at least 1 fraction with GDC ≤0.9 and GDC ≤0.8, respectively. Incidence of low GDC fractions among patients appeared stochastic. Patients with minimum GDC <0.8 trended toward more frequent grade 2 genitourinary toxicity compared with those with minimum GDC >0.8 (38% vs 18%, P = .065). Prostate intrafraction motion was mostly along the bladder-rectum axis and predominantly in the superior-anterior direction. Motion in the inferior-posterior direction was associated with significantly higher rate of acute grade 2 genitourinary toxicity (66.7% vs 13.9%, P = .001). Gating limited mean prostate motion during treatment delivery in fractions with a GDC <0.9 (<0.8) to 2.9 mm (2.9 mm) versus 4.1 mm (4.7 mm) for ungated motion. Fractions with large intrafraction motion were associated with increased toxicity and their occurrence among patients appears stochastic. Real-time tracking/gating effectively mitigated this motion and is likely a major contributing factor of acute toxicity reduction associated with MRgRT.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call